If you’re renovating, building, or inspecting a home in Florida, you might be wondering: What type of foam is actually allowed for draftstopping under the Florida Residential Plumbing Code? Itโs a criticalโbut often overlookedโdetail that impacts both fire safety and code compliance. Using the wrong material could lead to failed inspections, costly rework, or even serious safety hazards. In this guide, weโll break down exactly what the Florida code says about foam used for draftstopping, so you can stay compliant and protected.
What Is Draftstoppingโand Why Does It Matter in Florida Homes?
Draftstopping is a fire-safety technique used to limit the spread of flames and smoke through concealed spaces in buildingsโlike floor cavities, attics, or wall voids. In multi-family or multi-story homes, these hidden pathways can act like chimneys during a fire, accelerating its spread.
In Floridaโs humid, hurricane-prone climate, builders often use spray foam insulation not just for energy efficiency but also for air sealing. However, not all foams are approved for use as draftstopping, especially when installed near plumbing or electrical penetrations.
According to the Florida Building Code (FBC), Residential Volume, which adopts the International Residential Code (IRC) with state-specific amendments, draftstopping must meet specific fire-resistance and installation criteria.
๐ก Key Insight: The 2023 edition of the FBC references IRC Section R302.12 for draftstopping requirements in residential construction.
What Types of Foam Are Approved for Draftstopping in Florida?
This is where confusion often arises. Many assume that any expanding foam from the hardware store will doโbut only certain fire-rated foams qualify under code.
โ Approved Materials Include:
- Fire-retardant spray polyurethane foam (SPF) labeled for draftstopping or fireblocking.
- Intumescent foams that expand when exposed to heat, sealing gaps automatically.
- Foam sealants tested and listed to ASTM E814 or UL 1715 for through-penetration firestop systems.
โ Not Approved:
- Standard non-fire-rated expanding foam (e.g., generic โgap fillerโ cans).
- Foams without third-party certification (look for ICC-ES Evaluation Reports).
- Cellulose or fiberglass insulation used aloneโthey donโt provide an air barrier.
๐ Expert Tip: Always check the product label for โfireblockingโ or โdraftstoppingโ approval. If it doesnโt say it explicitly, it likely doesnโt comply.
For reference, the U.S. Department of Energy notes that while spray foam improves energy efficiency, its fire performance must align with local building codesโespecially in high-risk states like Florida (source).

How Floridaโs Code Defines Draftstopping Requirements
Per FBC Section R302.12, draftstopping is required in:
- Floor assemblies over crawlspaces or garages.
- Concealed horizontal spaces (like attic floors) exceeding 1,000 sq ft.
- Areas between dwelling units in townhomes or duplexes.
The code mandates that draftstops be made of materials equivalent to ยฝ-inch gypsum board, ยผ-inch wood structural panels, or other approved materialsโincluding specific foams.
Crucially, foam used for draftstopping must resist flame spread and limit smoke development. This is measured by:
- Flame Spread Index โค 25
- Smoke Developed Index โค 450
These values come from ASTM E84 (Standard Test Method for Surface Burning Characteristics).
| Material Type | Flame Spread Index | Smoke Developed Index | Code-Compliant in FL? |
|---|---|---|---|
| Standard SPF (non-rated) | 70โ200 | 300โ600 | โ No |
| Fire-Retardant SPF | โค25 | โค450 | โ Yes |
| Gypsum Board (ยฝ”) | 5โ10 | 0โ50 | โ Yes |
| Intumescent Foam Sealant | โค20 | โค300 | โ Yes |
Source: ICC-ES Evaluation Service Reports & FBC 2023
Step-by-Step: Installing Code-Compliant Foam for Draftstopping
Follow these steps to ensure your foam application meets Floridaโs residential plumbing and fire codes:
- Identify Draftstopping Zones
Locate areas requiring draftstopping per R302.12โtypically at midpoints of large floor cavities or between units. - Choose an Approved Foam Product
Select a foam with:- ICC-ES ESR report (e.g., ESR-3500 series)
- Label stating โapproved for fireblocking/draftstoppingโ
- Compliance with ASTM E814 or UL 1715
- Prepare the Area
Clean surfaces of dust, oil, or moisture. Ensure ambient temperature is between 60ยฐFโ90ยฐF (per most manufacturer specs). - Apply Foam Properly
- Fill gaps completely around plumbing pipes, ducts, or wiring penetrations.
- Use minimum 1 inch thickness for effective air sealing.
- Allow full cure time (usually 24 hours) before covering with drywall or flooring.
- Document Compliance
Keep product data sheets and ICC reports on file for inspection. Florida inspectors often request proof of material approval.
โ ๏ธ Warning: Never use plumbing pipe insulation foam (like Armaflex) for draftstoppingโitโs not fire-rated for this purpose.
Common Mistakes Contractors Make (and How to Avoid Them)
Even experienced builders slip up. Here are frequent errorsโand fixes:
- Mistake: Using โGreat Stuffโ regular foam for sealing around drainpipes.
Fix: Switch to Great Stuff Fireblock (specifically labeled for fireblocking). - Mistake: Assuming all โlow-expansionโ foams are safe.
Fix: Verify fire test ratingsโexpansion rate โ fire rating. - Mistake: Skipping documentation.
Fix: Save digital copies of ICC-ES reports; many are searchable at icc-es.org.
Remember: Floridaโs strict building codes exist for a reasonโhurricane resilience and fire safety go hand-in-hand in coastal construction.
FAQ Section
Q1: Is spray foam insulation the same as draftstopping foam?
A: No. While some spray foams can serve as draftstopping material, only those tested and labeled for fireblocking/draftstopping are code-compliant. Standard insulation foam lacks the necessary fire resistance.
Q2: Where exactly is draftstopping required in a Florida home?
A: According to FBC R302.12, draftstopping is required in concealed floor/ceiling assemblies larger than 1,000 sq ft, above garages, and between attached dwelling units (e.g., townhomes). Always consult your local building departmentโsome counties (like Miami-Dade) have stricter rules.
Q3: Can I use caulk instead of foam for draftstopping?
A: Only if itโs a fire-rated intumescent caulk approved for through-penetration firestopping. Regular silicone or acrylic caulk wonโt meet code.
Q4: Does the Florida Plumbing Code directly regulate foam?
A: Indirectly. While the plumbing code (FBC Plumbing Volume) governs pipe materials and venting, draftstopping falls under the Building Code (Residential Volume). However, since plumbing penetrations create gaps that require sealing, the two intersectโmaking foam selection a shared concern.
Q5: How do I verify if a foam product is approved in Florida?
A: Look for:
- An ICC-ES Evaluation Report (search at icc-es.org)
- Label stating compliance with ASTM E814 or UL 1715
- Explicit mention of โdraftstoppingโ or โfireblockingโ use
Q6: What happens if I fail inspection due to non-compliant foam?
A: Youโll likely need to remove and replace the foam with an approved productโa costly delay. In severe cases, it could affect your Certificate of Occupancy.
Conclusion
Understanding the Florida Residential Plumbing Code for type of foam for draftstopping isnโt just about passing inspectionโitโs about protecting lives and property. With the right fire-rated foam, proper installation, and documentation, you can ensure your project meets both safety standards and energy goals.
Donโt gamble with generic sealants. When fire safety is on the line, precision matters.
๐ Found this guide helpful? Share it with your contractor, builder, or DIY community on Facebook, LinkedIn, or Reddit! Letโs keep Florida homes safe, efficient, and code-compliantโone properly sealed gap at a time.
For more on building material safety standards, see the Wikipedia entry on firestops.