If you’re involved in residential or commercial construction in Australia—whether you’re a builder, plumber, architect, or homeowner—you’ve likely encountered the terms “Classes 1–10” and “Plumbing Code of Australia Volume 3.” But what do they actually mean, and how do they affect your project? Confusion around these classifications and plumbing requirements can lead to costly delays, compliance issues, or even safety risks. This guide breaks it all down clearly, so you can move forward confidently and in full compliance with Australian standards.
What Are Building Classes 1–10 in Australia?
Australia’s National Construction Code (NCC)—published by the Australian Building Codes Board (ABCB)—categorizes all buildings into 10 distinct classes based on their use, occupancy, and structure. These classifications directly influence which plumbing, drainage, and sanitation rules apply under Volume 3 of the Plumbing Code of Australia (PCA).
Here’s a quick reference:
Building Class
Description
Class 1
Detached houses or duplexes (Class 1a) and attached townhouses (Class 1b, if used for short-term accommodation)
Class 2
Multi-unit apartments (e.g., apartment blocks)
Class 3
Boarding houses, hotels, motels, dormitories
Class 4
A residence inside a non-residential building (e.g., caretaker’s flat in a warehouse)
Class 5
Office buildings
Class 6
Retail shops, cafés, hair salons
Class 7
Car parks (7a) or warehouses/storage (7b)
Class 8
Factories, labs, service stations
Class 9
Public buildings: schools (9a), hospitals (9b), assembly venues (9c)
💡 Key Insight: Only Class 1 and Class 10 buildings are covered under Volume 2 of the NCC (residential). Volume 3—the focus here—applies to Classes 2–9and certain Class 10 structures that contain plumbing (e.g., a detached toilet or laundry in a backyard shed).
What Is the Plumbing Code of Australia Volume 3?
Volume 3 of the Plumbing Code of Australia is part of the National Construction Code (NCC) and governs all plumbing and drainage installations for non-residential buildings (Classes 2–9), as well as Class 10 structures with plumbing fixtures.
Unlike Volume 2 (which targets standard homes), Volume 3 addresses complex systems like:
Commercial kitchen grease traps
Hospital medical gas and wastewater systems
Multi-story drainage stacks
Rainwater harvesting in public buildings
It sets mandatory performance requirements and offers deemed-to-satisfy (DTS) solutions—pre-approved methods that guarantee compliance.
📌 Expert Note: According to the ABCB, over 68% of plumbing non-conformances in commercial builds stem from misapplying Volume 2 rules to Volume 3 projects. Always verify your building class first.
How Do Classes 1–10 Affect Plumbing Compliance?
Not all buildings are treated equally under Australian plumbing law. Here’s how classification impacts your plumbing design:
✅ Class 1 & 10 (with plumbing)
Governed by Volume 2unless the Class 10 structure includes fixtures like toilets, showers, or sinks.
Example: A backyard studio with a bathroom must comply with Volume 3 if it’s classified as Class 10a with plumbing.
🔧 Classes 2–9
Strictly regulated under Volume 3.
Higher requirements for:
Pipe sizing and material durability
Ventilation of drainage systems
Backflow prevention
Accessibility (AS 1428.1 compliance)
🏗️ Real-World Case: In 2023, a Sydney apartment complex (Class 2) failed final inspection because plumbers used residential-grade PVC pipes. Volume 3 required chlorinated polyvinyl chloride (CPVC) for hot water above 60°C in multi-occupancy buildings.
Key Requirements in Volume 3 You Must Know
Volume 3 includes over 200 pages of technical specifications, but these are the 5 most critical areas for compliance:
Sanitary Drainage Systems
Minimum gradient: 1:40 for pipes ≤100mm, 1:60 for >100mm
Must include adequate ventilation to prevent siphonage
Water Supply & Efficiency
Maximum flow rates:
Showerheads: 9 L/min
Taps: 6 L/min (unless sensor-activated)
Mandatory water metering in commercial buildings
Onsite Wastewater Management
Required for buildings not connected to municipal sewer
Systems must meet AS/NZS 1546.1–4 standards
Stormwater Drainage
Must handle 1-in-20-year storm events (minimum)
Roof gutters sized per AS/NZS 3500.3
Backflow Prevention
Devices required for: irrigation systems, fire hose reels, medical labs
Even experienced contractors slip up. Here’s what to watch for:
Mistake
Consequence
Fix
Using Class 1 rules for a Class 3 boarding house
Rejected certification
Confirm class before design
Ignoring ventilation in long drainage runs
Foul odors, trap seal loss
Install relief vents every 10m
Installing non-compliant fixtures
Water waste, fines
Only use WaterMark-certified products
Misclassifying a granny flat
Wrong plumbing code applied
If it has a kitchen/bathroom, it’s likely Class 1b
Step-by-Step: Checking if Volume 3 Applies to Your Project
Follow this checklist:
Determine your building’s class using the NCC definitions (see table above).
Ask: Does it have any plumbing fixtures (toilet, sink, shower, etc.)?
If it’s Class 2–9 OR Class 10 with fixtures → Volume 3 applies.
Consult a licensed plumbing designer—especially for multi-story or high-occupancy builds.
Submit plans to your local council or private certifier for approval under NCC Volume 3.
✅ Tip: Use the ABCB’s free NCC Online tool (registration required) to access the full Volume 3 text and compliance guides.
FAQ Section
Q1: Does a backyard shed with a toilet fall under Volume 3?
A: Yes. Any Class 10 structure with plumbing (toilet, sink, shower) must comply with Volume 3 of the PCA, not Volume 2.
Q2: Are tiny homes covered under Class 1 or Volume 3?
A: It depends. If the tiny home is on a permanent foundation and used as a primary residence, it’s Class 1 (Volume 2). If it’s on wheels or used commercially (e.g., Airbnb), it may be Class 1b or Class 3, triggering Volume 3.
Q3: Can I use the same pipes for a house and an office building?
A: Not always. Volume 3 often requires higher-grade materials (e.g., copper or CPVC instead of standard PVC) due to greater usage, temperature, or pressure demands.
Q4: Who enforces the Plumbing Code of Australia?
A: Each state and territory has its own plumbing regulator (e.g., NSW Fair Trading, QBCC in Queensland). They conduct inspections and issue compliance certificates.
Q5: Is rainwater harvesting mandatory under Volume 3?
A: Not mandatory, but strongly encouraged. If installed, systems must meet AS/NZS 3500.1 and include backflow prevention.
Q6: Where can I access the full Plumbing Code of Australia Volume 3?
A: It’s published as part of the National Construction Code (NCC) and available free online at abcb.gov.au.
Conclusion
Navigating Classes 1–10 and Plumbing Code of Australia Volume 3 doesn’t have to be overwhelming. By understanding your building’s classification and applying the right plumbing standards from day one, you’ll avoid delays, reduce costs, and ensure safety and sustainability.
Whether you’re renovating a café (Class 6) or building student housing (Class 3), always double-check which volume of the NCC applies—and when in doubt, consult a licensed professional.